The choice of the optimal cation exchanger for local water sodium cycle installations

According to the following criteria: purity degree, physical and chemical properties, the comparison of samples of industrial strongly acidic cation exchangers in Na-form is made in this paper to substantiate their efficiency in water softening processes. Furthermore, we compare production costs of sodium cycling process in the course of concurrent regeneration with different consumption of NaCl and speeds of water passing. Overall, we discover that the strongly acidic cation exchanger Dowex Marathon C can be effectively applied in the local water softening installations of low and medium productivity.

Publication year: 
2008
Issue: 
1
УДК: 
621.182
С. 123–127, укр., Іл. 2. Табл. 3. Бібліогр.: 5 назв.
References: 

1. Лифшиц О.В. Справочник по водоподготовке котельных установок. — Изд. 2-е, перераб. и доп. — М.: Энергия, 1976. — 288 с.
2. Рябчиков Б.Е. Современные методы подготовки воды для промышленного и бытового использования. — М.: ДеЛи принт, 2004. — 301 с.
3. Водоподготовка: Справочник / Под ред. С.Е. Беликова. — М.: Аква-Терм, 2007. — 240 с.
4. ГОСТ 20298—74. Смолы ионообменные. Катиониты. Технические условия. Введено 01.03.1990 г.
5. Практикум по ионному обмену: Учеб. пос. / В.Ф. Селеменев, Г.В. Славинская, В.Ю. Хохлов и др. — Воронеж: Воронеж. гос. ун-т, 2004. — 160 с.